mirror of
https://git.familie-radermacher.ch/linux/ptouch-print.git
synced 2026-09-15 22:27:34 +00:00
print_img: correct off-center print area via per-device pin_offset
On the PT-P900W the print area is not centered on the 560-pin printhead: its center sits at pin 272 rather than the head center (pin 280), a fixed 8-pin offset that is constant across all tape widths. Centering the raster data on the head therefore prints ~0.5mm off-center (measured as a constant ~1mm margin delta across 12/18/36mm tapes, confirmed against the spec). Add a pin_offset field to _pt_dev_info (0 = centered, the default for all existing printers) and apply it in print_img. Set it to -8 for the PT-P900Wc, which reproduces the spec left-margin exactly for every tape width ((560-print_area)/2 - 8 = documented left margin). Reference: Brother "Software Developer's Manual - Raster Command Reference, PT-P900/P900W/P950NW", section 2.3.5 "Raster line" (per-tape left/right margin and print-area pin counts for the 560-pin head). https://download.brother.com/welcome/docp100407/cv_ptp900_eng_raster_102.pdf
This commit is contained in:
committed by
Dominic Radermacher
parent
9af6276135
commit
921206cd5f
+7
-2
@@ -89,10 +89,14 @@ struct _pt_dev_info ptdevs[] = {
|
||||
{0x04f9, 0x2074, "PT-D600", 128, 180, FLAG_RASTER_PACKBITS},
|
||||
/* PT-D600 was reported to work, but with some quirks (premature
|
||||
cutting of tape, printing maximum of 73mm length) */
|
||||
{0x04f9, 0x2085, "PT-P900Wc", 560, 360, FLAG_RASTER_PACKBITS|FLAG_P700_INIT|FLAG_USE_INFO_CMD|FLAG_HAS_PRECUT},
|
||||
{0x04f9, 0x2085, "PT-P900Wc", 560, 360, FLAG_RASTER_PACKBITS|FLAG_P700_INIT|FLAG_USE_INFO_CMD|FLAG_HAS_PRECUT, -8},
|
||||
/* PT-P900Wc: 360dpi, 560px printhead (70 bytes/raster line). Verified
|
||||
printing on 36mm laminated tape. Narrower tape widths use Brother's
|
||||
documented 360dpi print areas (see tape_info) but are untested. */
|
||||
documented 360dpi print areas (see tape_info) but are untested.
|
||||
pin_offset = -8: the print area is centred at pin 272, not the head
|
||||
centre (pin 280) - a constant offset across all tape widths. See the
|
||||
Brother "Software Developer's Manual - Raster Command Reference,
|
||||
PT-P900/P900W/P950NW", section 2.3.5 "Raster line". */
|
||||
{0x04f9, 0x20af, "PT-P710BT", 128, 180, FLAG_RASTER_PACKBITS|FLAG_HAS_PRECUT},
|
||||
{0x04f9, 0x20df, "PT-D410", 128, 180, FLAG_USE_INFO_CMD|FLAG_HAS_PRECUT|FLAG_D460BT_MAGIC},
|
||||
{0x04f9, 0x20e0, "PT-D460BT", 128, 180, FLAG_P700_INIT|FLAG_USE_INFO_CMD|FLAG_HAS_PRECUT|FLAG_D460BT_MAGIC},
|
||||
@@ -175,6 +179,7 @@ int ptouch_open(ptouch_dev *ptdev)
|
||||
(*ptdev)->devinfo->dpi=ptdevs[k].dpi;
|
||||
(*ptdev)->devinfo->max_px=ptdevs[k].max_px;
|
||||
(*ptdev)->devinfo->flags=ptdevs[k].flags;
|
||||
(*ptdev)->devinfo->pin_offset=ptdevs[k].pin_offset;
|
||||
return 0;
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue
Block a user